Full-Service Datacenters

Netrouting uses a variety of facilities in The Netherlands, Germany, Sweden and United States.

Netrouting 1 - Spijkenisse, The Netherlands

Netrouting operates it's own private regional datacenter facility in Spijkenisse. Netrouting has full network capacity available in Spijkenisse and offers all hosting and connectivity products at this location.

Strenghts:
- Carrier-Neutral datacenter
- 1/4-1/2-1/1 secured compartment racks
- 11.000+ sqt feet datacenter
- 1 Megawatt capacity available
- 100Mbit, 1Gigabit, 10Gigabit and trunked connectivity options
- Interconnect VLAN and dark fiber wave options
- 240Gbps+ external network capacity available
- Dark Fiber to TelecityRedbus2 Amsterdam, GlobalSwitch Amsterdam and R-iX Rotterdam
- Antenna towers available

Colohouse - Miami, United States

In April 2010 Netrouting opened up a presence in Miami. As a result of sustainable growth at our facility in Miami, it has evolved into a full-service datacenter for all of Netrouting's hosting and connectivity services.

Colohouse is a modern datacenter built under the highest of expectations. Netrouting and Colohouse have worked closely together over the years to maintain and grow the Netrouting infrastructure in Miami. Netrouting operates it's own backbone in Miami.

Strenghts:
- Carrier-Neutral datacenter
- 1/2-1/1 secured compartment racks
- 24.000+ sqt feet datacenter
- 1 Megawatt capacity available
- 10Mbit, 100Mbit, 1Gigabit, 10Gigabit and trunked connectivity options
- Netrouting powered diverse fiber routes to several datacenters in Miami, direct interconnection to Amsterdam
- Interconnect VLAN and dark fiber wave options
- Antenna towers available

Portlane - Stockholm, Sweden

Netrouting started in Sweden in 2009 for connectivity purposes and expanded to Portlane in 2011 to start offering Stockholm based hosting services.

Netrouting and Portlane carry a solid partnership to ensure the best possible product for you, the end-user. Netrouting operates it's own backbone in Sweden, interconnecting between multiple datacenters such as Availo (Phonera), TelecityRedbus2 Bromma and Portlane Nacka.

Strenghts:
- Carrier-Neutral datacenter
- Environmental Friendly Cooling
- Modular built datacenterr
- 3.3 megawatt high-voltage grid
- Netrouting powered diverse fiber routes to several datacenters in Stockholm, direct interconnection to Amsterdam
- Interconnect VLAN and dark fiber wave options
- Antenna towers available
Secured Access

Netrouting has an automated access system allowing customers to enter and leave the building according to the privileges set on their private access card. To prevent abuse or theft issues the card is disabled by default, you may activate your key with every visit to the datacenter by logging on to our Client Integration System (CIS). You'll be given a 7 digit code to enter in the computer upon arrival at the datacenter, without this code no access will be given to any of the data floors. Re-enter the 7 digit code upon leaving the building and your card will be disabled immediately.

CCTV Camera Security

For your and our safety, every hallway, every door and every floor is being monitored with a CCTV Camera system. Along with an automated alarm system it is safe to say that unauthorized access is simply impossible and every attempt to do so will be prevented. The CCTV Camera system registers by motion and is being monitored 24/7.

IP-Cam Control

For optimal security we also have several IP camera's in all of our cold-corridors to monitor activity near the servers. The cameras operate on motion detection and are being monitored 24/7.

VESDA Fire Control

A Very Early Smoke Detection Apparatus (VESDA) has been installed in every room. These easily triggered smoke detectors are connected to the Building Management System (BMS), which of course is being monitored 24/7 for both you and your equipment's safety. Any possible fire can be detected in an early stage allowing the fire control system to be activated and prevent any damage being done to your equipment.

Air Conditioning

To maintain a suitable environment for high performance, we equip all floors with remote controlled air conditioning units. These units are set to a threshold with a temperature of 21℃ +- 2℃, these temperatures are being monitored 24/7 by the Building Management System.

Power

Every connected rack has 2 isolated power feeds with backing of Uninterruptible Power Supply (UPS) systems to ensure availability.